Cord Length 6ft 1. Includes: CD with software, Cord management straps, email privacy, firewall, Free trial of anti-virus, system recovery and online backup software, USB cable, User manual.
Provides notification of changing utility power and UPS power conditions. Periodic battery self-test ensures early detection of a battery that needs to be replaced. Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery. Provides protection of connected equipment from power surges on the data lines.
Lifetime data recovery warranty Provides peace of mind by providing professional data recovery services in the event data is lost due to the failure of the unit. Boost and Trim Automatic Voltage Regulation AVR Automatically corrects low and high voltage conditions, allowing you to work through brownouts and overvoltages without discharging the battery.
This saves battery life, increases uptime, and improves your productivity. Serial connectivity Provides management of the UPS via a serial port. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Resettable circuit breakers Enables a quick recovery from overload events.
LED status indicators Quickly understand unit and power status with visual indicators. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced. Cold-start capable Provides temporary battery power when the utility power is out. Audible alarms Provides notification of changing utility power and UPS power conditions.
User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair MTTR. Transformer-block spaced outlets Protect equipment with input transformer blocks without blocking access to other receptacles. Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances. Battery-protected and surge-only outlets Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment.
Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Adjustable voltage sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. Intelligent battery management Micro-processor controlled battery charging and diagnostic testing ensures maximum battery life.
Adjustable voltage-transfer points Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. Virgin Islands.
Technical Specifications Print. Topology Line interactive. Waveform type Stepped approximation to a sinewave. Maximum Output Current Input frequency 47 - 63 Hz. Input voltage range for main operations 78 - Adjustable, 88 - V.
Number of Power Cords 1. Battery type Lead-acid battery. Included Battery Modules 1. Typical recharge time 8hour s. Replacement Battery RBC Expected Battery Life years 4 - 6. RBC Quantity 1. Battery Charge Power Watts 21 Watts. Runtime View Runtime Graph. Interface Port s USB. Control panel LED status display with on line : on battery : replace battery and overload indicators.
Reset push in the rear panel circuit breaker. Switch on the Back-UPS and plug in devices one at a time. If the circuit breaker trips again, disconnect the device that caused the breaker to trip. Connect battery cartridge see Connect Battery Cartridge. Unplug device from 'Surge Only' outlet and move to a 'Battery Backup' outlet. Switch the Back-UPS on and plug equipment in one-at-a-time.
Storage Temperature The standard warranty is two 2 years from the date of purchase. Customers who must have the original unit back due to the assignment of asset tags and set depreciation schedules must declare such a need at first contact with an APC Technical Support representative.
APC will ship the replacement unit once the defective unit has been received by the repair department, or cross-ship upon the receipt of a valid credit card number. The customer pays for shipping the unit to APC. APC pays ground freight transportation costs to ship the replacement unit to the customer. Unplug non-essential equipment printers, scanners, etc from the Battery Backup outlets and plug into 'Surge Only' outlets.
Weight 22 lbs 10 kg Back-UPS battery cartridge is discharged due to recent power outage and has not had time to recharge. Charge the battery cartridge for 8 hours. Back-UPS runtime is reduced until the battery cartridge is fully charged.
Replace battery cartridge see Order Replacement Battery Cartridge. Red Replace Battery indicator is flashing. Green On Line indicator is on. Internal battery cartridge is not connected. Red Replace Battery indicator is on. Battery has reached the end of its life. Replace the battery cartridge see Order Replacement Battery Cartridge. Red Overload indicator is on or flashing. Connected equipment is drawing more power than the Back-UPS can provide. Move one or more equipment power plugs from Battery Backup outlets to Surge Only outlets.
Green On Line indicator is on and all other front panel indicators are flashing. Internal UPS fault. The battery cartridge typically lasts years, shorter if subjected to frequent outages or elevated temperatures.
Order part number RBC Please recycle spent battery cartridges. Have the Back-UPS model number, serial number and date of purchase available. Consider adjusting the transfer voltage and sensitivity. See Transfer Voltage and Sensitivity Adjustment. Utility input voltage quality is out of range. Back-UPS does not provide expected backup time.
If the Back-UPS arrived damaged, notify the carrier.