Unattended operation of this product could result in personal injury or property damage. To reduce the risk of fire, do not allow the compressor to operate unattended.
Always operate the compressor in a well ventilated area free of combustible materials, gasoline, or solvent vapors. If spraying flammable materials, locate compressor at least 20 feet away from spray area. An additional length of hose may be required. Never place objects against or on top of compressor. Operate compressor in an open area at least 12 inches away from any wall or obstruction that would restrict the flow of fresh air to the ventilation openings.
Operate compressor in a clean, dry well ventilated area. Do not operate unit indoors or in any confined area. Always remain in attendance with the product when it is operating. Always disconnect electrical power by moving pressure switch lever to the off position and drain tank daily or after each use.
Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. Never drill into, weld, or make any modi-. Unauthorized modifications to the unloader valve, safety valve, or any other components which control tank pressure. Excessive vibration can weaken The tank is designed to withstand specific.
The compressed air stream can cause soft tissue damage to exposed skin and can propel dirt, chips, loose particles , and small objects at high speed , resulting in property damage or personal injury. Never point any nozzle or sprayer toward any part of the body or at other people or animals. Always turn the compressor off and bleed pressure from the air hose and tank before attempting maintenance, attaching tools or accessories. Your air compressor is powered by electricity.
Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution. Electrical Grounding: Failure to provide adequate grounding to this product could result in serious injury or death from electrocution. Never operate the compressor outdoors when it is raining or in wet conditions.
Never operate compressor with protective covers removed or damaged. Any electrical wiring or repairs required on this product s hould be performed by authorized service center personnel in accordance with national and local electrical codes.
Make certain that the electrical circuit to which the compressor is connected provides proper electrical grounding, correct voltage and adequate fuse protection. The compressed air directly from your compressor is not safe for breathing. The air stream may contain carbon monoxide, toxic vapors, or solid particles from the tank. Breathing these contaminants can cause serious injury or death. Sprayed materials such as paint, paint solvents, paint remover, insecticides, weed killers, may contain harmful vapors and poisons.
Air obtained directly from the compressor should never be used to supply air for human consumption. In order to use air produced by this compressor for breathing, suitable filters and in-line safety equipment must be properly installed.
In-line filters and safety equipment used in conjunction with the compressor must be capable of treating air to all applicable local and federal codes prior to human consumption. Work in an area with good cross ventilation.
Read and follow the safety instructions provided on the label or safety data sheets for the materials you are spraying.
Touching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation. Do not reach around protective shrouds or attempt maintenance until unit has been allowed to cool.
A portable compressor can fall from a table, workbench, or roof c ausing damage to the compressor and could result in serious injury or death to the operator. Always operate compressor in a stable secure position to prevent accidental movement of the unit. Never operate compressor on a roof or other elevated position.
Use additional air hose to reach high locations. Oil can leak or spill and could result in fire or breathing hazard; serious injury or death can result. Unsafe operation of your air compressor could lead to serious injury or death to you or others. Review and understand all instructions and warnings in this manual. Become familiar with the operation and controls of the air compressor. A choice of discharge port sizes in the cylinder for ideal internal compression.
And an almost unlimited spectrum of possible adaptations and accessories. Designed for the compression of air, nitrogen, and other neutral gases, the Delta Screw compressors are perfect for almost any possible application. The new VM E-Compressor also offers extensive modifications and a versatile range of accessories. When it comes to versatility, the compressors in the Delta Screw series exceed all expectations. The largest number of possible modifications.
And the broadest range of accessories. In other words: the right compressor for all process requirements. No compromises. Oil-free-screw-compressor Process gas compressors Air compressors Biogas compressor.
Acoustic evaluations Machine diagnosis Training Machine registration. Use only a fuse or circuit breaker that is the same rating as the branch circuit on which the air compressor is operated. If compressor is connected to a circuit protected by fuses, use only time delay fuses.
Welcome to ManualMachine. We have sent a verification link to to complete your registration. Log In Sign Up. Forgot password? Enter your email address and check your inbox. Please check your email for further instructions. Enter a new password. Delta User Manual Download for 1. D Rev. Indicates an Indicates a imminently hazardous potentially hazardous situation which, if not avoided, will situation which, if not avoided, may result in death or serious injury.
Used without the Indicates a potentially safety alert symbol hazardous situation which, if not indicates a potentially hazardous avoided, could result in death or situation which, if not avoided, may serious injury. D 2- ENG. What Could Happen It is normal for electrical contacts within the motor and pressure switch to spark.
How To Prevent It Always operate the compressor in a well ventilated area free of combustible materials, gasoline, or solvent vapors. Store flammable materials in a secure location away from compressor. Failure to properly drain Drain tank daily or after each use. If condensed water from tank, tank develops a leak, replace it causing rust and thinning of the immediately with a new tank or replace steel tank.
Modifications or attempted repairs Never drill into, weld, or make any to the tank. Unauthorized modifications to the attachments. Excessive vibration can weaken The tank is designed to withstand specific the air tank and cause rupture or operating pressures. Never make explosion adjustments or parts substitutions to alter the factory set operating pressures. Follow the can cause them to explode or fly apart, equipment manufacturers and could result in serious injury.
D 4- ENG. See grounding instructions. Attempting to operate compressor with Any repairs required on this product damaged or missing parts or attempting should be performed by authorized to repair compressor with protective service center personnel. D 6- ENG. Never defeat the safety features of this product.
Equip area of operation with a fire extinguisher. Do not operate machine with missing, broken, or unauthorized parts. D 8- ENG. You can only view or download manuals with. Sign Up and get 5 for free. Upload your files to the site. You get 1 for each file you add. Get 1 for every time someone downloads your manual. Buy as many as you need.